CPRI Fiber Patch Cords are widely used in FTTA BBU-DDU, Base Station application. Shenzhen Inte Supplies 5.0mm both Armored and Unarmored Cable Type to meet customers' different application scenario
Fiber Parameters
No. | Items | Unit | Specification | |
G.657A2 | ||||
1 | Mode Field Diameter | 1310nm | μm | 9.2±0.4 |
1550nm | μm | 10.4±0.5 | ||
2 | Cladding Diameter | μm | 125±0.7 | |
3 | Cladding Non-Circularity | % | ≤0.7 | |
4 | Core-Cladding Concentricity Error | μm | ≤0.5 | |
5 | Coating Diameter | μm | 245±5 | |
6 | Coating Non-Circularity | % | ≤6.0 | |
7 | Cladding-Coating Concentricity Error | μm | ≤12.0 | |
8 | Cable Cutoff Wavelength | nm | λcc≤1260 | |
9 | Attenuation(max.) | 1310nm | dB/km | ≤0.35 |
1550nm | dB/km | ≤0.25 |
Cable Parameters
Items | Specifications | |
Fiber Count | 2 | |
Tight Buffer Fiber | Dimension | 0.87±0.03mm |
Material | LSZH | |
Fiber Color | Blue、 Orange | |
Outer Jacket | Dimension | 5.0±0.2mm |
Material | FR-LSZH | |
Thickness | 1.0±0.05mm | |
Col | Black | |
Strength Member | Strengthen component | Aramid Yarn
|
Mechanical and Environmental Characteristics
Items | Unit | Specifications |
Tensile Strength(Long Term) | N | 300 |
Tensile Strength(Short Term) | N | 600 |
Crush(Long Term) | N/250px | 100 |
Crush(Short Term) | N/250px | 500 |
Min. Bend Radius(Dynamic) | mm | 20D |
Min. Bend Radius(Static) | mm | 10D |
Installation Temperature | ℃ | -20~+60 |
Operating Temperature | ℃ | -20~+60 |
Storage Temperature | ℃ | -20~+60 |
Patch cord parameters:
Type | SM | MM | ||
Characteristics | UPC | APC | UPC | PC |
Insertion loss(dB) | ≤0.2dB | ≤0.2dB | ≤0.3dB | 0.3dB |
Return loss (dB) | ≥50dB | ≥60dB | ≥50dB | ≥35dB |
Attenuation(Maximum) | 0.4dB@1310nm 0.3dB@1550nm | 0.4dB@1310nm 0.3dB@1550nm | 3.0dB@850nm 1.2dB@1300nm | 3.0dB@850nm 1.2dB@1300nm |
Attenuation(dB) | SM:1310 nm≤0.35dB/km;1550 nm≤0.25dB/km MM:850 nm≤3.0dB/km; 1300 nm≤1.0dB/km | |||
Durability(dB) | ≥1000/Matings | |||
Operating Temperature(dB) | -40℃~ +70℃ | |||
Bending Radius | Dynamic 30D Static 10D |